A single voltage spike can bring a production line to a sudden stop. It can damage a PLC, affect a drive or disrupt a sensor network. In many cases, the cost of downtime can be higher than the cost of repairing or replacing the damaged equipment. That's why electrical surge protection devices for industrial facilities are now a basic piece of plant equipment rather than an optional addition.
This guide looks at how they work, what types are used, where they go, how to select them, how to maintain them and what the common mistakes are so you can be confident your plant will keep running through lightning, grid faults and heavy load switching.
What Are Electrical Surge Protection Devices and How Do They Work?
A surge is a very brief, sharp rise in voltage (microseconds). The SPD (surge protection device) is the unit in your panel that handles it. It's in parallel with the supply and does absolutely nothing under normal running conditions. When the voltage does go above a safe level, it switches from high to low impedance in nanoseconds, shifts the excess current to earth and thus limits the voltage that reaches your equipment. It then switches back to its high impedance state again.
Most AC SPDs use components such as metal oxide varistors (MOVs) to respond to voltage spikes. These components help limit excess voltage and direct the surge current through the appropriate discharge path. Two important ratings to check are the discharge current, measured in kA, and the protection level (Up), which indicates the voltage that can reach connected equipment during a surge. These features play an important role in electrical surge protection for industrial equipment.
An SPD is not a UPS or a voltage stabilizer. A UPS keeps equipment running during a power cut, while a stabilizer helps manage changes in the supply voltage. An SPD is designed to handle short-duration voltage spikes. To understand the technical work, read our complete guide on How Does a Surge Protection Device Work.
Why Do Industrial Facilities Need Surge Protection?
There are many causes of voltage surges that can be found in industrial plants. Induced voltage surges are picked up by long cable runs and structures, and switching voltage surges can be created by such devices as motors, compressors, and transformers. So, surge protection in an industrial plant is needed because electrical machinery should work properly. Voltage surges normally occur from three sources:
- Lightning needn't actually strike the plant. A strike some distance away will induce voltage in the cables and monsoon storms make that a very common occurrence throughout India.
- Switching: motors, compressors, transformers, capacitor banks and welding machines all generate surges every time they start or stop. Most of the surges in a plant are going to be generated in the plant.
- Grid events: Utility switching operations and supply faults can also cause voltage spikes that enter the facility through the incoming power supply.
The damage isn't always obvious. Small surges will slowly degrade the electronics so PLCs, VFDs, HMIs and sensors all start to fail in all sorts of odd ways, which leads to stopped lines and late deliveries. That's why industrial surge protection devices are now at the heart of a plant's safety plan. A single SPD at the gate is simply not sufficient. You need a full industrial surge protection system built in layers.
What Types of Surge Protection Devices Are Used in Industrial Facilities?
SPDs are grouped in a number of ways. For AC power systems, SPDs are commonly classified as Type 1, Type 2 and Type 3, based on their intended application and testing requirements. More information on the various types of SPDs is available in our guide to types of surge protection devices. In a plant, you'll normally encounter these:
Type 1 SPD
Type 1 SPDs are generally installed at the main incomer when the facility has an external lightning protection system or when the installation requires protection against partial lightning currents. It's tested with a 10/350 µs wave and is therefore capable of taking part of the direct lightning current that is coming in via the cables.
Type 2 SPD
Type 2 is the workhorse of plant protection. It's the type you find at the main panel, the PCC, the MCC, and the sub-distribution boards. It's tested with an 8/20 µs wave and is designed to deal with the residual lightning surges as well as the switching surges generated within the plant itself. Most layered industrial surge protection system designs rely on it.
Type 3 SPD
Type 3 SPDs are installed close to sensitive equipment such as PLCs, control panels and drives. They provide an additional level of protection against the remaining voltage surges. They should be used along with suitable upstream protection and not as a standalone solution.
AC and DC SPDs
AC SPDs provide protection to the mains distribution system. DC SPDs provide protection to the solar PV modules, the inverters, the battery and the DC control circuits. A DC circuit lacks the inherent zero crossing that is inherent in an AC circuit. Therefore, DC SPDs have been designed with ratings and components appropriate to DC applications. It is not advisable to install an AC SPD on a DC circuit. Signal/Data Line SPDs are another type of SPDs.
You can browse Blitz’s range of surge protection devices products for AC and DC systems. For photovoltaic applications, DC SPDs should also meet the relevant requirements of IEC 61643-31.
Check out this guide to learn more about the difference between AC SPD and DC SPD.
Where Should Surge Protection Devices Be Installed in Industrial Facilities?
Where you put your electrical surge protection devices for industrial facilities is every bit as important as which ones you actually select. You need to think in layers, from the point where the power comes into the plant right through to the equipment at the other end.
- Main incomer or PCC: The first stage that takes the big outside surges before they get through the plant.
- MCCs and sub-distribution boards: These provide the next level of protection against surges that pass through the main SPD, along with switching surges generated by motors, compressors and other equipment.
- Critical equipment: PLC panels, VFDs, SCADA and instrumentation. A surge that's small by plant standards can still be damaging.
- DC side: Solar inverters, combiner boxes and battery systems (all of which will require their own DC-rated protection).
Protection should also be coordinated between the different SPD stages so that each device can handle the surges expected at its installation point.
Keep the leads between the SPD and the busbar as short and straight as possible, have a solid earth, and fit the backup fuse or MCB as specified in the datasheet. Long or looped leads will add voltage that the SPD can't get rid of. Adhere to the manufacturer's recommendations with regard to cable length between stages and have a qualified electrician carry out the installation. For the full process, see our guide on how to install surge protection device.
How to Choose the Right Surge Protection Device for Industrial Plants
The right unit is going to be one that's appropriate for your system, not the one with the biggest number on the label. These are the main checks:
- System voltage and earthing: The nominal voltage (Un) and the maximum continuous operating voltage (Uc) must be suitable for your supply and your earthing arrangement (TN, TT or IT).
- Poles: Match the pole count to the supply, e.g. 4 poles for a 3-phase, 4-wire board.
- Type: Select by exposure and location as above.
- Discharge current: In and Imax will tell you how much surge energy the unit can take. The main exposed panels will need higher ratings.
- Protection level (up): Lower is better as that's the voltage that actually gets to your equipment.
- Indication: A status window and a remote signalling contact to make monitoring easier.
- DC rating: Solar and battery circuits will need a DC unit rated for the system voltage.
- Environment: Heat, dust and humidity are all important so check the temperature range and the type of enclosure.
- Standard: Look for IEC 61643-11.
A good SPD for industrial plants is one that's appropriate for your panel and your exposure. For larger installations, you'd want to get an electrical consultant to confirm the ratings. Not sure where to start? Our guide on choosing the right surge protection device goes into much more detail on each of these points.
Common Surge Protection Mistakes to Avoid in Industrial Operations
- One SPD at the entrance only. Any surges generated inside the plant never get through to the entrance SPD.
- Wrong UC: A unit that doesn't match the system voltage either fails early or protects poorly.
- Long or looped leads: They can increase the voltage during surge discharge and reduce the level of protection provided by the SPD.
- Weak earthing: Without a good earth, the surge has nowhere to go.
- Incorrect backup protection: Not installing the recommended backup fuse or MCB can affect the safe operation of the SPD.
- Ignoring the DC side: Some solar installations have AC-side protection but lack suitable protection for DC circuits. Both sides should be assessed.
- Buy on kA or price alone: An industrial surge protector has to be the right one for the job and for the location.
- No coordination between stages: Components installed without proper verification of wire lengths and voltage ratings will not be able to distribute the surge properly.
- Ignoring a red indicator: An inactive unit will leave the circuit without protection.
- Skip the inspection and testing entirely: The one that is out of order can appear the same as the one that works normally until you actually check it.
How to Maintain and Inspect Industrial Surge Protection Devices
Maintenance is simple and surge protection device inspection and testing takes you through the full routine. Simply check the status window on a regular basis and after every storm or grid fault. If the status indicator shows a fault condition, check the manufacturer's instructions and arrange for the SPD to be replaced if required. If the optional remote signaling contact is fitted, then wire it to the PLC or SCADA so that an alarm gets to the control room.
Once a year, have an electrician check the earth continuity, terminal tightness and any heat marks or discoloration on each SPD. Keep a simple log of the condition of each unit and have a spare on hand for the critical panels (a failed SPD leaves the circuit completely unprotected). After a major lightning event, check the earths and the wiring as well. Replace by condition, not by calendar.
Why Choose Blitz Energy India for Surge Protection Devices?
Blitz Energy India designs and manufactures AC SPDs and DC SPDs, DC MCBs and PV solar fuses in India. The AC SPDs are Type 2 (Class II) units with a nominal 20 kA and a maximum discharge current of 40 kA, a protection level of 1.5 kV or less and a response time of 25 ns or less. They are 35 mm DIN rail mounted with a Green/Red status window and an optional remote signaling contact. For solar plants, they have DC SPDs available at 600 V and 1000 V.
Blitz Energy India's products are manufactured at its 50,000+ sq. ft. facility, supported by automated quality control processes and a zero-defect policy. The company also supplies to more than eight countries and provides after-sales support. Its AC and DC surge protection range offers solutions for different industrial and solar applications, making it a suitable option for businesses looking for an industrial surge protector, an SPD for industrial plants, or electrical surge protection devices for industrial facilities in India.
Conclusion
Electrical surge protection devices for industrial facilities are best achieved via a layered approach: the correct type of device at each level, good earth, short leads and regular inspection. You want to plan the layers in relation to the actual source of the surge, match the device to its supply and treat inspection as part of the regular maintenance regime. That's how you keep your plant protected through the monsoon, grid faults and heavy load switching.